    Thermal Mass Flow Meters

    Thermal Mass Flow Meters are used to accurately measure the mass flow of liquid or gases in systems.

    We partner with McMillan to supply Thermal Mass Flow Meters and Controllers that feature fast response times, virtually zero maintenance and precise measurement.

    What are Thermal Mass Flow Meters and How Do They Work?

    Thermal Mass Flow Meter Operating PrincipleFor example, the McMillan Model 50X Series Mass Flow Meters utilise thermal sensing technology. Flow enters the unit, and a portion of the flow is redirected into a small tube. This tube has two coils, one downstream from the other. The first coil introduces a small amount of heat into the gas stream. As the gas passes through the tube, the smart electronics sense the amount of heat transferred from one coil to the other. McMillan’s proprietary design system ensures that the zero remains stable and the sensor is extremely repeatable.

    The output of the thermal mass flow sensor is directly related to the specific heat characteristic of the gas being measured. Therefore, if a unit is calibrated for air, it is a relatively simple calculation to figure the calibration for nitrogen or some other similar gas. This advantage offers flexibility not found on many other types of flow sensors.

    Mass Flowmeters vs. Mass Flow Controllers

    The McMillan RHODIUM Series Mass Flow Controllers utilise MEMS thermal sensing technology.

    MEMS technology utilises a compact, reliable CMOS (Complementary Metal Oxide Semiconductor) sensor. This no-drift sensor module is comprised of both the electronic and mechanical elements on a single silicon chip, similar to the process used for integrated circuits.

    Thermal Mass Flow Controller Operating Principle

    Flow enters the unit, and a portion of the flow is redirected into a chamber and across the MEMS device. This device has two temperature sensors, one downstream from the other. Between the coils sits a small heating element, as shown in the image to the right. As the gas passes through the device, the smart electronics sense the difference in heat between the two sensors, since the upstream coil is not exposed to the heated gas. The downstream coil senses the heated gas and McMillan’s advanced sensing algorithm calculates the flow rate based on the difference in value. The precision manufacturing and compact size of the MEMS device insure that the zero remains stable and the sensor is extremely repeatable.

    Flow then passes into the proportional solenoid valve. This valve is controlled by the active servo electronics, which compare a setpoint (supplied via analogue input signal) to the actual flow rate provided by the flow sensor and adjust the valve accordingly.

    How to Select a Flow Measuring Device

    • Flow Ranges – consider what flow range is required for measurement and/or control (eg. 0 – 20 sccm or 0 – 500  L/min)
       
    • Power – what supply power is required? Units may be required to operate with either 12 VDC or 24 VDC power.
       
    • Signal Inputs & Outputs – for example 0 – 5 VDC or 4 to 20 mA linear outputs are common options.
       
    • Accuracy/Linearity – are there any specific accuracy requirements for the device? Do you
      require NIST traceable calibration certificates?
       
    • Fluid Connections – typical options include compression type tube fittings or flare fittings (sizes usually ranging from 1/8″ – 1/2″ depending on flow range).
       
    • Electrical Connections – typical units are utilising 36″ output cables terminating with a 6-PIN PS/2 style connector, with optional mating cable assemblies available.
       
    • Wetted Materials – consider what is the flowing media and chemical compatibility. We can offer units in Stainless Steel, Brass, PTFE and more.
       
    • Displays – do you require an integral LCD display?
       
    • Calibration Gases – units may be calibrated for virtually any clean, dry gases.

    Why choose Boiswood?

    For your MCMILLAM RHODIUM GAS MASS FLOW CONTROLLER

    World-class quality products

    Quality Products & Service Levels

    World-class quality products backed by unrivalled service levels. We only partner with the best manufacturers in industry. You can trust in our 35+ years of experience.

    Competitively priced products

    Competitive Pricing Structures

    Competitively priced products that we strive to keep consistent. We always ensure special pricing structures are considered.

    Attractive lead times

    Excellent Delivery Schedules

    Attractive lead times that are monitored and managed, ensuring customers receive on-time deliveries. We can also ship our products internationally.

    unmatched response times

    Ultra-Fast Response Times

    Tired of chasing for answers? We pride ourselves on our unmatched response times. You can rely on us to provide extremely quick answers to technical and commercial queries.

    On-going support

    Free Technical Support

    On-going support for our customers to meet any evolving technical requirements. We can help size and specify solutions for even the most bespoke applications.

    right solution for your application

    OEM & Custom Configurations

    We sit alongside design teams to specify the right solution for your application, no matter how demanding. Whether it’s out-of-the-box or a custom design, we are up for the challenge.

    ever-growing stock profile

    Tailored Stocking Profiles

    Need your products tomorrow? We’ve got you covered with our ever-growing stock profile and product portfolio. We can hold stock for you based on your consumption rates.

    in-house servicing, testing and assembly

    Servicing & Assembly Capabilities

    Official and manufacturer certified in-house servicing, testing and assembly for our core products, including custom panels and subassemblies.

    0
    Your Quote List
    Your quote list is empty